Arctic Package
The top-mount pump control panel in the BATROPS walkway is sealed to contain heat. The rear pump area is sealed to contain heat around the pump, reel and plumbing. Two 25,000 BTU heaters are installed, one in the pump panel enclosure and one in the rear enclosure. The heaters are wired and controlled independently. All exposed aluminum on the truck is treated with Sharkhide for protection from the harsh environment. If a foam system is chosen, the foam tank with be incorporated into the water tank. If CAFS is chosen, air blow out capabilities will be added to the plumbing.